2TLA010050R0100
Sentry SSR10M Safety relay ABB Jokab Safety
Sentry SSR10M Safety relay with relay outputs 3NO+1NC, 85-265 VAC/120-375 VDC supply voltage and screw terminals.
For monitoring of safety devices with contacts, 2 equivalent channels.
Manual or automatic reset selectable by switch on front.
Sentry safety relays cover various types of safety applications up to PLe / SIL3.
Basic models provide reliable supervision of simpler safety functions, while universal models provide advanced features and high flexibility.
Models with display offer preset configurations and extensive information to further simplify troubleshooting.
Additional variants offer a high accuracy timer function of ± 1% and an adjustable time setting range from 0-999 s.
High output current capacity of up to 6 A can save the use of an intermediary contactor. Multi-reset allows up to 10 safety relays connected to one reset light-button.
All models are available with detachable push-in or screw terminals. Terminals and coding kit to mark removed terminals are available as accessories.
ABB Jokab Safety Relay, Screw Terminals, 120 (W) x 120 (H) x 22.5mm (W) – Sentry SSR10M Series – 2TLA010050R0100
Features & Benefits
• Manual or automatic reset function triggered by a switch on the front for ease of use
• Safety controller’s outputs can be expanded to improve functionality
Applications
• Industrial automation
• Mining equipment
How heavy is this safety relay?
What’s this component’s supply voltage?
คุณสมบัติ | Value |
Supply Voltage | 265 V ac, 375V dc |
Number of Channels | 2 |
Safety Contacts | 4 |
Function | Safety Switch |
Auxiliary Contacts | 3 |
Reset Method | Multi-Reset |
Range | Sentry |
Safety Category ISO 13849-1 | 4 |
PL ISO 13849-1 | e |
SIL IEC 61508 | 3 |
Terminal Type | Screw |
Configurable | Yes |
Standards Met | CE |
Depth | 120mm |
Series | SSR10M |
Width | 120mm |
Length | 22.5mm |
Performance Level | e |
Sentry SSR10 | 2TLA010050R0000 | SSR | Safety relay | Safety relay with relay outputs 3NO+1NC, +24 VDC supply voltage and screw terminals. For monitoring of safety devices with contacts, 1 or 2 equivalent channels, and safety devices with OSSD outputs. Manual or automatic reset selectable by switch on front. |
Sentry SSR10P | 2TLA010050R0001 | SSR | Safety relay | Safety relay with relay outputs 3NO+1NC, +24 VDC supply voltage and push-in spring terminals. For monitoring of safety devices with contacts, 1 or 2 equivalent channels , and safety devices with OSSD outputs. Manual or automatic reset selectable by switch on front. |
Sentry SSR10M | 2TLA010050R0100 | SSR | Safety relay | Safety relay with relay outputs 3NO+1NC, 85-265 VAC/120-375 VDC supply voltage and screw terminals. For monitoring of safety devices with contacts, 2 equivalent channels. Manual or automatic reset selectable by switch on front. |
Sentry SSR10MP | 2TLA010050R0101 | SSR | Safety relay | Safety relay with relay outputs 3NO+1NC, 85-265 VAC/120-375 VDC supply voltage and push-in spring terminals. For monitoring of safety devices with contacts, 2 equivalent channels. Manual or automatic reset selectable by switch on front. |
Sentry SSR20 | 2TLA010051R0000 | SSR | Safety relay | Safety relay with relay outputs 3NO+1NC, +24 VDC supply voltage and screw terminals. For monitoring of two-hand devices. Manual or automatic reset selectable by switch on front. |
Sentry SSR20P | 2TLA010051R0001 | SSR | Safety relay | Safety relay with relay outputs 3NO+1NC, +24 VDC supply voltage and push-in spring terminals. For monitoring of two-hand devices. Manual or automatic reset selectable by switch on front. |
Sentry SSR20M | 2TLA010051R0100 | SSR | Safety relay | Safety relay with relay outputs 3NO+1NC, 85-265 VAC/120-375 VDC supply voltage and screw terminals. For monitoring of two-hand devices. Manual or automatic reset selectable by switch on front. |
Sentry SSR20MP | 2TLA010051R0101 | SSR | Safety relay | Safety relay with relay outputs 3NO+1NC, 85-265 VAC/120-375 VDC supply voltage and push-in spring terminals. For monitoring of two-hand devices. Manual or automatic reset selectable by switch on front. |
Sentry SSR32 | 2TLA010052R0400 | SSR | Safety relay | Safety relay with relay outputs 2NO+2 delayed NO, +24 VDC supply voltage and screw terminals. For monitoring of safety devices with contacts, 1 or 2 equivalent channels, and safety devices with OSSD outputs. Manual or automatic reset selectable by switch on front.he two delayed NO relay outputs have an OFF-delay time of 0,5 second. |
Sentry SSR32P | 2TLA010052R0401 | SSR | Safety relay | Safety relay with relay outputs 2NO+2 delayed NO, +24 VDC supply voltage and push-in spring terminals. For monitoring of safety devices with contacts, 1 or 2 equivalent channels , and safety devices with OSSD outputs. Manual or automatic reset selectable by switch on front. The two delayed NO relay outputs have an OFF-delay time of 0,5 second. |
Sentry SSR42 | 2TLA010053R0400 | SSR | Safety relay | Safety relay with relay outputs 2NO+2 delayed NO, +24 VDC supply voltage and screw terminals. For monitoring of safety devices with contacts, 1 or 2 equivalent channels , and safety devices with OSSD outputs. Manual or automatic reset selectable by switch on front. The two delayed NO relay outputs have an OFF-delay time of 1,5 seconds. |
Sentry SSR42P | 2TLA010053R0401 | SSR | Safety relay | Safety relay with relay outputs 2NO+2 delayed NO, +24 VDC supply voltage and push-in spring terminals. For monitoring of safety devices with contacts, 1 or 2 equivalent channels , and safety devices with OSSD outputs. Manual or automatic reset selectable by switch on front. The two delayed NO relay outputs have an OFF-delay time of 1,5 seconds. |