2TLA010052R0401
Sentry SSR32P Safety relay with relay outputs 3NO+1NC, 85-265 VAC/120-375 VDC supply voltage and push-in spring terminals.
For monitoring of safety devices with contacts, 2 equivalent channels.
Manual or automatic reset selectable by switch on front.
Sentry safety relays cover various types of safety applications up to PLe / SIL3.
Basic models provide reliable supervision of simpler safety functions, while universal models provide advanced features and high flexibility.
Models with display offer preset configurations and extensive information to further simplify troubleshooting.
Additional variants offer a high accuracy timer function of ± 1% and an adjustable time setting range from 0-999 s.
High output current capacity of up to 6 A can save the use of an intermediary contactor. Multi-reset allows up to 10 safety relays connected to one reset light-button.
All models are available with detachable push-in or screw terminals. Terminals and coding kit to mark removed terminals are available as accessories.
Sentry SSR10 | 2TLA010050R0000 | SSR | Safety relay | Safety relay with relay outputs 3NO+1NC, +24 VDC supply voltage and screw terminals. For monitoring of safety devices with contacts, 1 or 2 equivalent channels, and safety devices with OSSD outputs. Manual or automatic reset selectable by switch on front. |
Sentry SSR10P | 2TLA010050R0001 | SSR | Safety relay | Safety relay with relay outputs 3NO+1NC, +24 VDC supply voltage and push-in spring terminals. For monitoring of safety devices with contacts, 1 or 2 equivalent channels , and safety devices with OSSD outputs. Manual or automatic reset selectable by switch on front. |
Sentry SSR10M | 2TLA010050R0100 | SSR | Safety relay | Safety relay with relay outputs 3NO+1NC, 85-265 VAC/120-375 VDC supply voltage and screw terminals. For monitoring of safety devices with contacts, 2 equivalent channels. Manual or automatic reset selectable by switch on front. |
Sentry SSR10MP | 2TLA010050R0101 | SSR | Safety relay | Safety relay with relay outputs 3NO+1NC, 85-265 VAC/120-375 VDC supply voltage and push-in spring terminals. For monitoring of safety devices with contacts, 2 equivalent channels. Manual or automatic reset selectable by switch on front. |
Sentry SSR20 | 2TLA010051R0000 | SSR | Safety relay | Safety relay with relay outputs 3NO+1NC, +24 VDC supply voltage and screw terminals. For monitoring of two-hand devices. Manual or automatic reset selectable by switch on front. |
Sentry SSR20P | 2TLA010051R0001 | SSR | Safety relay | Safety relay with relay outputs 3NO+1NC, +24 VDC supply voltage and push-in spring terminals. For monitoring of two-hand devices. Manual or automatic reset selectable by switch on front. |
Sentry SSR20M | 2TLA010051R0100 | SSR | Safety relay | Safety relay with relay outputs 3NO+1NC, 85-265 VAC/120-375 VDC supply voltage and screw terminals. For monitoring of two-hand devices. Manual or automatic reset selectable by switch on front. |
Sentry SSR20MP | 2TLA010051R0101 | SSR | Safety relay | Safety relay with relay outputs 3NO+1NC, 85-265 VAC/120-375 VDC supply voltage and push-in spring terminals. For monitoring of two-hand devices. Manual or automatic reset selectable by switch on front. |
Sentry SSR32 | 2TLA010052R0400 | SSR | Safety relay | Safety relay with relay outputs 2NO+2 delayed NO, +24 VDC supply voltage and screw terminals. For monitoring of safety devices with contacts, 1 or 2 equivalent channels, and safety devices with OSSD outputs. Manual or automatic reset selectable by switch on front.he two delayed NO relay outputs have an OFF-delay time of 0,5 second. |
Sentry SSR32P | 2TLA010052R0401 | SSR | Safety relay | Safety relay with relay outputs 2NO+2 delayed NO, +24 VDC supply voltage and push-in spring terminals. For monitoring of safety devices with contacts, 1 or 2 equivalent channels , and safety devices with OSSD outputs. Manual or automatic reset selectable by switch on front. The two delayed NO relay outputs have an OFF-delay time of 0,5 second. |
Sentry SSR42 | 2TLA010053R0400 | SSR | Safety relay | Safety relay with relay outputs 2NO+2 delayed NO, +24 VDC supply voltage and screw terminals. For monitoring of safety devices with contacts, 1 or 2 equivalent channels , and safety devices with OSSD outputs. Manual or automatic reset selectable by switch on front. The two delayed NO relay outputs have an OFF-delay time of 1,5 seconds. |
Sentry SSR42P | 2TLA010053R0401 | SSR | Safety relay | Safety relay with relay outputs 2NO+2 delayed NO, +24 VDC supply voltage and push-in spring terminals. For monitoring of safety devices with contacts, 1 or 2 equivalent channels , and safety devices with OSSD outputs. Manual or automatic reset selectable by switch on front. The two delayed NO relay outputs have an OFF-delay time of 1,5 seconds. |