2TLA020054R0300 ABB Tina 4A DYNlink connection accessory

2TLA020054R0300

ABB Tina 4A DYNlink connection accessory

Tina 4A is a connection block for series connection of up to four DYNlink devices. Four M12-5 female connectors for the sensors are available on the device. The information signal of each device can be wired separately. The cable used for the connection to the Tina 4A should have a diameter 7 – 12 mm. Unused M12-connectors on Tina 4A must be equipped with Tina 1A blind plugs.

The Tina devices adapt the DYNlink safety circuit in Vital, Pluto and B&R X20 to safety components with mechanical contacts, such as E-stops, switches and light beams/curtains with dual outputs.

Tina is available in several versions depending on the type of safety component that is connected to the Vital, Pluto or B&R X20 circuit.

หมวดหมู่:

2TLA020054R0300

ABB Tina 4A DYNlink connection accessory

Dimensions

  • Product Net Depth / Length:
    50 mm
  • Product Net Height:
    45 mm
  • Product Net Width:
    119 mm
  • Product Net Weight:
    0.095 kg

Technical

  • Suitable For:
    Pluto AS-i v2
    Pluto A20 v2
    Pluto B20 v2
    Pluto B22
    Pluto B42 AS-i
    Pluto B46 v2
    Pluto D20
    Pluto D45
    Pluto D45 (Harsh Env)
    Pluto O2
    Pluto S20 v2
    Pluto S46 v2
    Vital 1
    B&R X20

Pluto Safety PLC, Base Unit

Pluto from ABB is an “All-Master” safety PLC concept, which simplifies the design of safety systems and achieves the highest safety category 4 according to EN 954-1. All Pluto’s are Master units and can see the other Pluto’s inputs, outputs and global memories. This enables the Pluto to evaluate the information from the other Pluto’s and then take decisions concerning its own safety devices. The Gateway units are available for several different bus systems, i.e. Profibus (733-4836), CanOpen (733-4830), Devicenet (733-4849) and Ethernet (733-4842). Of Pluto’s inputs (the smallest unit has 16 I/O), thus can be configured as either inputs or outputs. In the Pluto family by ABB most modules have dual safety outputs – potential free or PNP types. In a two-wire bus system up to 32 Pluto units can be safely connected and communicate with a superior system via a Gateway or HMI displays. Therefore within a maximum extended system 1472 I/O’s can be connected. Also all input components may be connected in series for even more complexity and optimisation.

Simple and easy programming facilities
Easy to configure and install
Up to 640 I/O’s
Multiple Plutos can be connected on a bus (via using the IDFIX identifier) and then further interfaced with external networks by using a Gateway, typical example RS stock number (733-4842)
High safety level
Free software available
Programming over the bus
35 mm DIN rail mounting
The IDFIX (733-4824) is an identification circuit which allows multiple Plutos to be identified when connected on a bus system. This module is available to distribute a PLC program within a network of Pluto devices.
Tina adapters such as (733-2477) can be used to connect external safety monitoring equipment

Note
The IDFIX device (733-4824) is connected between the input terminals ID and 0V (also note that the IDFIX device is not required when using a single Pluto, however the absense of an IDFIX requires to be stated when programming the Pluto device.)
Approvals
TUV, FS, CSA
Standards
European Machinery Directive 2006/42/EC
EN ISO 12100-1, EN ISO 12100-2,
EN 60204-1, EN 954-1, EN ISO 13849-1,
EN 62061