Nidec E300 Elevator AC Drives
Introducing the dedicated Elevator Drive
Adding value at every stage of your project
Freedom to design
|
|
Effortless installation and commissioning
|
|
Class-leading performance
|
|
Maintenance and diagnostics support
|
- Features
Rapid set-up and adjustment
- Simple and intuitive parameter adjustment via a bright back-lit LCD keypad
- Set-up in familiar elevator language and units
- Easy to use menu structure for quick and simple access to key adjustments
- Top level menu; all your frequently needed functions in one location
- Stationary autotune provides encoder phasing test without the need to de-rope the system or to open the motor brakes
Optimum ride comfort
- Direct-to-floor positioning
- Peak curve operation
- High resolution multi-step S-ramp for start, run, slowdown and stopping
- Ultra-fast current loop for vibration free motor control
- Advanced brake control management, no rollback on starting without the need of load sensor
Silent operation
- EN81-20 / EN81-50 TÜV certified STO enable input removes the need for both output motor contactors
- High switching frequencies selectable up to 16 kHz
- Variable speed cooling fan
Energy efficient
- Standby sleep/wake mode, powers down unused circuitry during prolonged periods of standby
- Easy connection to a range of regenerative modules
Flexible integration
- Modbus RTU communications
- Parallel I/O interface
- +/- 10V analog reference control
- Direct RS485 comms control
- DCP3 and DCP4 communication support with optional System Integration module
- CANopen communication support with optional System Integration module
- Tile mount for low profile shaft mounting
- 24 Vdc backup
- Simple UPS connection with load direction signal
- Dynamic braking transistor fitted to all drives as standard
Robust
- Active thermal management for tripless operation under extreme conditions
- Advanced power circuit design using latest IGBT technology
- Conformal coating for use in harsh environments
- Phase loss detection on both input and output
Enhanced elevator data logger
- User configurable, for example speed reference, speed feedback, current and I/O sequence can all be recorded for every car journey
- Can be stored in the event of system fault
- Available for offline viewing to aid system diagnostics
- Specifications
Key data
- Dedicated Elevator drive:
Standard features
Onboard comms:-
RS485 communications port MODBUS RTU with integrated command word and built in watchdog
Safety:-
1 x Safe Torque Off (STO) terminal
-
SIL3/PLe compliant
Keypad:- Dedicated elevator keypad supplied as standard, providing:
- Intuitive elevator application menu structure
-
Easy click-in keypad connection
-
Easy-to-use menu and parameter structure
-
Local and remote mounting
-
Real-time clock
Option slots:- 3
Parameter cloning via:- PC tools
- Smartcard
- SD card
200 – 240 Vac, 50-60 Hz ± 10 % Drive RatingsPART NUMBER CURRENT (A) Peak Current Nominal Current 03200106A10 21.2 10.6 04200137A10 27.413.7 04200185A10 37 18.5 05200250A10 50 25 06200330A10 66 33 06200440A10 88 44 07200610A10 122 61 07200750A10 150 75 07200830A10 166 83 08201160A10 232 116 08201320A10 264 132 09201760A10 352 176 09202190A10 438 219 10202830A 566 283 10203000A 600 300 For all aboveSwitching frequency 8 KHz (selectable 3 to 16 kHz @ 50 % ED)Braking transistor built in as standard380 – 480 Vac, 50-60 Hz ± 10 % Drive Ratings
PART NUMBER CURRENT (A) Peak Current Nominal Current 03400062A10 11 6.2 03400078A10 147.8 03400100A10 18 10 04400150A10 27 15 04400172A10 31 17.2 05400220A10 39 22 05400270A10 48 27 05400300A10 53 30 06400350A10 62 35 06400420A10 74 42 06400470A10 83 47 07400660A10 116 66 07400770A10 135 77 07401000A10 175 100 08401340A10 235 134 08401570A10 275 157 09402000A10 350 200 09402240A10 385 220 10402700E 473 270 10403200E 543 310 For all aboveSwitching frequency 8 KHz (selectable 3 to 16 kHz @ 50 % ED)Braking transistor built in as standard500 – 575 Vac, 50-60 Hz ± 10 % Drive Ratings
PART NUMBER CURRENT (A) Peak Current Nominal Current 05500030A10 5.5 3 05500040A10 74 05500069A10 12 6.9 06500100A10 17.5 10 06500150A10 26.5 15 06500190A10 33.5 19 06500230A10 40.5 23 06500290A10 51 29 06500350A10 54.5 31 07500440A10 77 44 07500550A10 96.5 55 08500630A10 110.5 63 08500860A10 150.5 86 09501040A10 182 104 09501310A10 229.5 131 10501520E10 266 152 10501900E10 332.5 190 For all aboveSwitching frequency 8 KHz (selectable 3 to 16 kHz @ 50 % ED)Braking transistor built in as standard690 Vac, 50-60 Hz ± 10 % Drive RatingsPART NUMBER CURRENT (A) Peak Current Nominal Current 07600190A10 33.5 19 07600240A10 42 24 07600290A10 51 29 07600380A10 66.5 38 07600440A10 77 44 07600540A10 84 48 08600630A10 110.5 63 08600860A10 150.5 86 09601040A10 182 104 09601310A10 229.5 131 10601500E10 262.5 150 10601780E10 311.5 178 For all aboveSwitching frequency 8 KHz (selectable 3 to 16 kHz @ 50 % ED)Braking transistor built in as standardFurther information from your supplier is available on the following features:
• UPS operation – all drives have a dedicated rescue mode allowing operation from 200 V UPS
• DC supply – all drives have the possibility of being supplied from a DC source from 24 V to the maximum voltage rating of the product
• 500 V, 525 V, 575 V and 690 V units are also available